The course will be sent out only after the purchaser fills out the Student Course Assignment Form.
Some of the topics in Book I are applied sprinkler technology, piping materials, piping supports, basic building layout, sprinkler spacing rules, and fundamentals of sprinkler system layout.
6Â Modules
Upon completion, the student will receive 21.6 CEUs (216 hours).
Module A  Introduction to Applied Sprinkler Technology (36 Hours)
- Lesson 1Â Â Some Basic Things About Your Job as a Sprinkler Designer
- Lesson 2Â Â An Overview of Fire Protection and Fire Protection Sprinkler Systems
- Lesson 3Â Â History and Evolution of the Automatic Fire Sprinkler
- Lesson 4Â Â Types of Systems
Module B  Piping Materials (45 Hours)
- Lesson 5Â Â Overhead Piping Materials
- Lesson 6Â Â Piping Materials and Joints
- Lesson 7Â Â Copper Tubing
- Lesson 8Â Â Polybutylene Piping Systems
- Lesson 9Â Â CPVC Plastic Piping Systems
Module C      Piping Supports (18 Hours)
- Lesson 10Â Â Hangers and Supports
- Lesson 11Â Â Protection of Piping Subject to Earthquake
Module D      Basic Building Layout (36 Hours)
- Lesson 12Â Â Â Â Â Â Â Design Drawings and Specifications
- Lesson 13Â Â Â Â Â Â Â Construction Types
- Lesson 14Â Â Â Â Â Â Â Elements of a Building Layout
- Lesson 15Â Â Â Â Â Â Â Drawing of a Background
Module E  Sprinkler Spacing Rules (36 Hours)
- Lesson 16Â Â Occupancies and Hazard Classification
- Lesson 17Â Â Â Standard Sprinkler Spacing
- Lesson 18  Specific Sprinklers – Spacing and Position
- Lesson 19   Other Specific Sprinklers – Spacing, Location, and Position
Module F  Fundamentals of Sprinkler System Layout (45 Hours)
- Lesson 20 Â Layout of Sprinklers
- Lesson 21 Â Â Types of System Configurations
- Lesson 22Â Â Preliminary Piping Layout
- Lesson 24 Â Â Final Drawings
- Lesson 23 Â Â Coordination
5Â Modules
Upon completion, the student will receive 18.0 CEUs (180 hours).
Module G  Introduction to Calculations (36 Hours)
- Lesson 1Â Â Introduction to Basic Hydraulics
- Lesson 2Â Â Introduction to Water Supplies
- Lesson 3Â Â Water Demand Requirements
- Lesson 4Â Â Pipe Schedule Systems
Module H      Advanced Calculations (36 Hours)
- Lesson 5Â Â Hand Calculations to End Sprinkler
- Lesson 6  Hand Calculations – Branch Line to Main
- Lesson 7  Hand Calculations – Main to Source
- Lesson 8Â Â Computer Calculations and Plan Submittal with Calculations
Module I  System Types (45 Hours)
- Lesson 9Â Â Wet Systems
- Lesson 10Â Â Antifreeze Systems
- Lesson 11Â Â Dry Pipe Systems
- Lesson 12Â Â Preaction Systems
- Lesson 13Â Â Deluge Systems
Module J  Fundamental Materials (36 Hours)
- Lesson 14Â Â Material Takeoff
- Lesson 15Â Â Sleeving
- Lesson 16Â Â Volumes, Surface Areas, Piping Offsets, etc.
- Lesson 17Â Â Drains
Module KÂ Â Support Systems (27 Hours)
- Lesson 18Â Â Standpipes and Hose Connections
- Lesson 19  Fire Department Pumper Connections and Inspector’s Tests
- Lesson 20 Â Underground and Backflow
5 Modules
Upon completion, the student will receive 15.3 CEUs (153 hours).
Module LÂ Â General Information (18 Hours)
- Lesson 1Â Â Â Codes and Standards
- Lesson 2Â Â Metric Units and Conversions
Module MÂ Â Pumps and Tanks (18 Hours)
- Lesson 3Â Â Stationary Pumps for Fire Protection
- Lesson 4Â Â Tanks in Fire Protection Design
Module N  Storage Design (18 Hours)
- Lesson 5Â Â Storage Criteria
- Lesson 6Â Â Fire Protection Design for Rack Storage Systems
Module O  Specialty Systems (63 Hours)
- Lesson 7Â Â Low Expansion Foam Fire Protection
- Lesson 8Â Â Flow Control Systems
- Lesson 9 Â Â Exposure Protection
- Lesson 10Â Â Water Spray Systems
- Lesson 11 Â Â Special Hazard Fire Suppression Systems: Carbon Dioxide, Clean Agent, Dry Chemical, and Wet Chemical
- Lesson 12Â Â Water Mist
- Lesson 13Â Â Alarm and Detection
Module PÂ Â Administrative (36 Hours)
- Lesson 14Â Â Inspection and Maintenance
- Lesson 15Â Â Project Management
- Lesson 16Â Â Introduction to Estimating Automatic Fire Sprinkler Systems
- Lesson 17Â Â Contracts, Letter of Proposal, and Change Orders