Learn about the changes made to NFPA 25 and the proposed changes for NFPA 13 that relate to backflow preventer installation and testing. The prescriptive installation requirements for backflow preventers, including test headers and flow rates, have matured over the last few revision cycles. Additionally, NFPA 25 has needed to adapt to the changes accordingly. Both standards will be examined as they relate to backflow preventer installation and testing.
Upon completion of this webinar, participants should be able to:
- Identify the proposed changes in NFPA 13 regarding test headers for backflow preventers.
- Determine the appropriate flows to test the backflow preventer.
- Apply the proper inspection, testing, and maintenance intervals per NFPA 25.
- Understand the intent of NFPA 13 and 25 in regards to flow measurement/verification.
John August Denhardt, P.E., ET, FSFPE, CWBSP
John August Denhardt, P.E., ET, FSFPE, CWBSP, is Vice President of Engineering and Technical Services for AFSA. He is a Professional Engineer (P.E.) registered in the District of Columbia as well as the states of Delaware, Maryland, Pennsylvania, and Virginia. He is a NICET Level III in Automatic Sprinkler System Layout and Inspection and Testing of Water-Based Systems and an NFPA Certified Water-Based Systems Professional (CWBSP). He is a member of the NFPA 13 Sprinkler Discharge Committee and is a Fellow in the Society of Fire Protection Engineers (SFPE). Denhardt is a National Fire Protection Association (NFPA) Research Foundation trustee, sits on the University of Maryland Department of Fire Protection Engineering’s Board of Visitors, and is a member of the SFPE Board of Directors. A native of Maryland, Denhardt holds a Bachelor of Science degree in Fire Protection Engineering from the University of Maryland in College Park.
Kevin Hall, M.Eng., P.E., ET, CWBSP, PMSFPE
Kevin Hall, M.Eng., P.E., ET, CWBSP, PMSFPE, is the coordinator of engineering and technical services for the American Fire Sprinkler Association (AFSA). He is a member of, and involved in, several National Fire Protection Association (NFPA) technical committees responsible for developing the model codes and standards including, NFPA 1 Fire Code, NFPA 13/13R/13D Installation of Sprinkler Systems, NFPA 20 Installation of Stationary Fire Pumps for Fire Protection, NFPA 30 Flammable and Combustible Liquids Code, and NFPA 915 Remote Inspections. He also represents AFSA on numerous UL standard technical panels responsible for revising and maintaining the product standards used in the sprinkler industry. He is a registered professional engineer in Delaware and Maryland, NICET III certified in water-based system layout, a Certified Water-Based System Professional (NFPA), and a professional member of the Society of Fire Protection Engineers. He earned his Bachelor of Science and Master of Engineering degrees from the University of Maryland, College Park in fire protection engineering. Prior to his association and committee work, he worked for Reliance Fire Protection in Baltimore, Maryland as a project manager overseeing projects of various sizes and complexity for the Contracts Division.