This webinar will review changes made to sprinkler discharge requirements during the latest revision cycle to NFPA 13 contained within the 2022 edition of the newly adopted standard. Specific changes that will affect the sprinkler contractor will be highlighted.
Upon completion of this webinar, participants should be able to:
- Identify significant changes proposed for the next edition of NFPA 13.
- Apply the requirements for single-point densities.
- Identify chapter layout and location of design requirements for storage applications based on applied sprinkler technology, introduced in the 2019 edition of NFPA 13.
- Identify clarifications made to the hydraulic calculation procedures.
John August Denhardt, P.E., ET, FSFPE, CWBSP
John August Denhardt, P.E., ET, FSFPE, CWBSP, is Vice President of Engineering and Technical Services for AFSA. He is a Professional Engineer (P.E.) registered in the District of Columbia as well as the states of Delaware, Maryland, Pennsylvania, and Virginia. He is a NICET Level III in Automatic Sprinkler System Layout and Inspection and Testing of Water-Based Systems and an NFPA Certified Water-Based Systems Professional (CWBSP). He is a member of the NFPA 13 Sprinkler Discharge Committee and is a Fellow in the Society of Fire Protection Engineers (SFPE). Denhardt is a National Fire Protection Association (NFPA) Research Foundation trustee, sits on the University of Maryland Department of Fire Protection Engineering’s Board of Visitors, and is a member of the SFPE Board of Directors. A native of Maryland, Denhardt holds a Bachelor of Science degree in Fire Protection Engineering from the University of Maryland in College Park.
Kevin Hall, M.Eng., P.E., ET, CWBSP, PMSFPE
Kevin Hall, M.Eng., P.E., ET, CWBSP, PMSFPE, is the coordinator of engineering and technical services for the American Fire Sprinkler Association (AFSA). He is a member of, and involved in, several National Fire Protection Association (NFPA) technical committees responsible for developing the model codes and standards including, NFPA 1 Fire Code, NFPA 13/13R/13D Installation of Sprinkler Systems, NFPA 20 Installation of Stationary Fire Pumps for Fire Protection, NFPA 30 Flammable and Combustible Liquids Code, and NFPA 915 Remote Inspections. He also represents AFSA on numerous UL standard technical panels responsible for revising and maintaining the product standards used in the sprinkler industry. He is a registered professional engineer in Delaware and Maryland, NICET III certified in water-based system layout, a Certified Water-Based System Professional (NFPA), and a professional member of the Society of Fire Protection Engineers. He earned his Bachelor of Science and Master of Engineering degrees from the University of Maryland, College Park in fire protection engineering. Prior to his association and committee work, he worked for Reliance Fire Protection in Baltimore, Maryland as a project manager overseeing projects of various sizes and complexity for the Contracts Division.