BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//American Fire Sprinkler Association - ECPv6.15.20//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://firesprinkler.org
X-WR-CALDESC:Events for American Fire Sprinkler Association
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20220313T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20221106T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20230312T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20231105T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20240310T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20241103T070000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20220101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;VALUE=DATE:20230425
DTEND;VALUE=DATE:20230520
DTSTAMP:20260423T024731
CREATED:20221214T212646Z
LAST-MODIFIED:20230130T180055Z
UID:10000183-1682380800-1684540799@firesprinkler.org
SUMMARY:Beginning Design School
DESCRIPTION:The Beginning Design School presents a comprehensive\, practical approach to preparing fire sprinkler system drawings. \nOver a three-week period\, students will attend six live webinars studying and reviewing the installation and design approach requirements of NFPA 13 (2019) while completing self-paced exercises and module assessments. Q&A sessions and open discussions will also be included as part of the online instruction. \nThe second part of the class will be a week of in-person training preparing fire sprinkler system layout\, shop drawings\, and hydraulic calculations by hand. The course concludes with a comprehensive exam of the class content including the installation requirements and hydraulics. \nThere is no CAD or third-party software taught in this class. \nLearning Objectives:\nThe school will prepare the student to: \n\nAccelerate the comprehension of plans and various types of building construction for proper sprinkler spacing applications.\nDetermine the proper and economic planning of sprinkler system layout and installation methods.\nKnow the importance of sprinkler specifications\, types of pipe\, hangers\, fittings\, flow tests\, etc.\nLearn to develop shop drawings from start to finish.\nLearn to coordinate with other trades – plumbing\, mechanical\, structural\, and electrical.\nPerform manual hydraulic calculations by hand\, preparing the student for a more natural decision-making process when using a computer to perform hydraulics.\nPrepare shop drawings in class for projects with different applications.\n\nPrerequisites:\nThis class is designed for trainees and entry-level technicians with at least six months of experience as well as those with experience in the sprinkler trade looking to make the transition to system layout. \nJuly – San Diego; September – Dallas; November – Orlando \nThe final week of each session will be hosted on location. Hotel location TBD. \nMore Info & Register
URL:https://firesprinkler.org/calendarevent/beginning-fire-sprinkler-system-planning-school-3/
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2021/06/Design_school_drawing.jpg
ORGANIZER;CN="AFSA":MAILTO:training@firesprinkler.org
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20230503T110000
DTEND;TZID=UTC:20230503T120000
DTSTAMP:20260423T024731
CREATED:20230220T191457Z
LAST-MODIFIED:20230220T191457Z
UID:10000202-1683111600-1683115200@firesprinkler.org
SUMMARY:Extended Coverage/Residential Sprinkler Obstructions
DESCRIPTION:Extended coverage sprinklers and residential sprinklers are both known for the larger floor areas they are able to protect.  How does this get impacted by obstructions?  Learn what items are considered obstructions and the needed distances from the sprinklers in order to adequately protect the space.  Not every obstruction can be avoided\, but NFPA 13 provides guidance for many common scenarios. \nLearning Objectives: \n1.    Explain the impact of obstructions on extended coverage sprinklers.\n2.    Explain the impact of obstructions on residential sprinklers.\n3.    Discuss the variations in the rules for pendent\, upright\, and sidewall styles.\n4.    Use the obstruction guidelines to locate extended coverage and residential sprinklers efficiently. \n  \n Learn More and Register\n  \nDetails:  \nRegistration Fees (per person): \nAFSA  Member Without CEU: FREE\nAFSA Member With CEU: $25.00\nAHJ Without CEU: FREE\nAHJ With CEU: $15\nNon-Member: $250 \nContinuing Education Credit: \nThis webinar offers: 0.1 CEUs\, 1.0 CPDs \nTo receive continuing education credits for the webinar\, you must do all of the following: \n\nRegister individually using your name that matches your fitter certification\, if applicable.\nConnect with your unique webinar link.\nDo not share or use someone else’s unique webinar link.\nAttend the webinar in its entirety\nRespond to each checkpoint question\nSubmit a completed evaluation form within 14 days of the webinar\n\nPlease check your time zone to ensure you connect at the right time: \n9:00 AM – 10:00 AM Pacific Time \n10:00 AM – 11:00 AM Mountain Time \n11:00 AM – 12:00 PM Central Time \n12:00 PM – 1:00 PM Eastern Time 
URL:https://firesprinkler.org/calendarevent/extended-coverage-residential-sprinkler-obstructions/
LOCATION:Online Webinar
CATEGORIES:Webinar
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2021/06/installing3.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20230517T110000
DTEND;TZID=UTC:20230517T120000
DTSTAMP:20260423T024731
CREATED:20230220T191847Z
LAST-MODIFIED:20230328T145406Z
UID:10000203-1684321200-1684324800@firesprinkler.org
SUMMARY:Sprinkler System Working Plan Requirements (CAL FIRE)
DESCRIPTION:This course will detail the requirements for working plans. This course will discuss the importance of the items required on working plans for approvals and submission. Specific topics include water supply information\, equipment\, hangers\, and bracing. \n Learn More and Register\n  \nLearning Objectives: \n1.    Identify the information that is required to be located on the working plans\n2.    Understand the requirements when changes to the working plans are made in the field \nDetails:  \nRegistration Fees (per person): \nAFSA  Member Without CEU: FREE\nAFSA Member With CEU: $25.00\nAHJ Without CEU: FREE\nAHJ With CEU: $15\nNon-Member: $250 \nContinuing Education Credit: \nThis webinar offers: 0.1 CEUs\, 1.0 CPDs \nTo receive continuing education credits for the webinar\, you must do all of the following: \n\nRegister individually using your name that matches your fitter certification\, if applicable.\nConnect with your unique webinar link.\nDo not share or use someone else’s unique webinar link.\nAttend the webinar in its entirety\nRespond to each checkpoint question\nSubmit a completed evaluation form within 14 days of the webinar\n\nPlease check your time zone to ensure you connect at the right time: \n9:00 AM – 10:00 AM Pacific Time \n10:00 AM – 11:00 AM Mountain Time \n11:00 AM – 12:00 PM Central Time \n12:00 PM – 1:00 PM Eastern Time 
URL:https://firesprinkler.org/calendarevent/sprinkler-system-working-plan-requirements/
LOCATION:Online Webinar
CATEGORIES:Fitter Zone,Webinar
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2022/07/Fitter_hangs_pvc_pipe.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20230531T110000
DTEND;TZID=UTC:20230531T120000
DTSTAMP:20260423T024731
CREATED:20230220T192348Z
LAST-MODIFIED:20230220T192348Z
UID:10000204-1685530800-1685534400@firesprinkler.org
SUMMARY:Fire Pumps: The Good\, Bad\, & Ugly
DESCRIPTION:Where needed\, fire pumps are essential to a water-based suppression system. Selecting the most efficient driver and pump is critical to a successful and profitable installation project. This seminar examines determining the need for a fire pump and choosing the proper pump capacity. The latest pump installation requirements\, including those for multi-stage\, multi-port pumps\, are reviewed. The latest information and requirements for acceptance testing and periodic inspection\, testing\, and maintenance are discussed\, along with the most efficient methods for assuring compliance with the standards. This seminar concludes with a review of some common issues and mistakes made when designing\, installing\, and inspecting/testing fire pumps. \nLearning Objectives: \n1.    Determine the need for a fire pump\, calculate the most efficient pump capacity\, and select the best driver for the application\n2.    Locate and apply the latest requirements for fire pump installation\n3.    Locate and apply the latest requirements for acceptance testing and periodic inspection and testing of fire pumps\n4.    Explain common mistakes made when designing\, installing\, and maintaining fire pumps\, along with potentially negative consequences \n  \n Learn More and Register\n  \nDetails:  \nRegistration Fees (per person): \nAFSA  Member Without CEU: FREE\nAFSA Member With CEU: $25.00\nAHJ Without CEU: FREE\nAHJ With CEU: $15\nNon-Member: $250 \nContinuing Education Credit: \nThis webinar offers: 0.1 CEUs\, 1.0 CPDs \nTo receive continuing education credits for the webinar\, you must do all of the following: \n\nRegister individually using your name that matches your fitter certification\, if applicable.\nConnect with your unique webinar link.\nDo not share or use someone else’s unique webinar link.\nAttend the webinar in its entirety\nRespond to each checkpoint question\nSubmit a completed evaluation form within 14 days of the webinar\n\nPlease check your time zone to ensure you connect at the right time: \n9:00 AM – 10:00 AM Pacific Time \n10:00 AM – 11:00 AM Mountain Time \n11:00 AM – 12:00 PM Central Time \n12:00 PM – 1:00 PM Eastern Time 
URL:https://firesprinkler.org/calendarevent/fire-pumps-the-good-bad-ugly/
LOCATION:Online Webinar
CATEGORIES:Webinar
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2022/05/185A0850-scaled.jpg
END:VEVENT
END:VCALENDAR