BEGIN:VCALENDAR
VERSION:2.0
PRODID:-//American Fire Sprinkler Association - ECPv6.15.20//NONSGML v1.0//EN
CALSCALE:GREGORIAN
METHOD:PUBLISH
X-ORIGINAL-URL:https://firesprinkler.org
X-WR-CALDESC:Events for American Fire Sprinkler Association
REFRESH-INTERVAL;VALUE=DURATION:PT1H
X-Robots-Tag:noindex
X-PUBLISHED-TTL:PT1H
BEGIN:VTIMEZONE
TZID:America/Chicago
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20220313T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20221106T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20230312T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20231105T070000
END:STANDARD
BEGIN:DAYLIGHT
TZOFFSETFROM:-0600
TZOFFSETTO:-0500
TZNAME:CDT
DTSTART:20240310T080000
END:DAYLIGHT
BEGIN:STANDARD
TZOFFSETFROM:-0500
TZOFFSETTO:-0600
TZNAME:CST
DTSTART:20241103T070000
END:STANDARD
END:VTIMEZONE
BEGIN:VTIMEZONE
TZID:UTC
BEGIN:STANDARD
TZOFFSETFROM:+0000
TZOFFSETTO:+0000
TZNAME:UTC
DTSTART:20220101T000000
END:STANDARD
END:VTIMEZONE
BEGIN:VEVENT
DTSTART;TZID=America/Chicago:20231004T110000
DTEND;TZID=America/Chicago:20231004T120000
DTSTAMP:20260422T101422
CREATED:20230809T205418Z
LAST-MODIFIED:20230809T205446Z
UID:10000222-1696417200-1696420800@firesprinkler.org
SUMMARY:Electric & Diesel Fire Pump Controller Drivers/Starting Method Differences
DESCRIPTION:This course will start off with a brief overview of both electric and diesel fire pump controllers and their selection\, followed by a more detailed review of the various drivers/starting methods – (Across the Line\, Part Winding\, Primary Resistor\, Autotransformer\, Wye-Delta Open/Closed\, Soft Start and Variable Frequency Drive – (VFD). We’ll then discuss which starting method(s) are most widely used today and why. Their advantages\, disadvantages\, and typical cost… \nLearning Objectives: \nUpon completion of this webinar\, attendees will be able to: \n\nDefine all aspects of both the Electric and Diesel Fire Pump Controllers.\nIdentify the differences between each Fire Pump Controller Driver/Starting Method.\nSelect the best Driver/Starting Method for the project application\nDefine the distinct operation differences between Soft Start and VFD starting methods\n\nSpeaker: Marty Tomasic – Director of Global Sales (Tornatech Inc.) \n  \n Register & More Information\n 
URL:https://firesprinkler.org/calendarevent/electric-diesel-fire-pump-controller-drivers-starting-method-differences/
LOCATION:Online Webinar
CATEGORIES:Webinar
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2022/05/185A0850-scaled.jpg
END:VEVENT
BEGIN:VEVENT
DTSTART;TZID=UTC:20231014T100000
DTEND;TZID=UTC:20231014T110000
DTSTAMP:20260422T101422
CREATED:20230220T194853Z
LAST-MODIFIED:20231009T135330Z
UID:10000209-1697277600-1697281200@firesprinkler.org
SUMMARY:Sprinkler Types & Characteristics (CAL FIRE)
DESCRIPTION:This webinar details differences in sprinkler types and considerations for design and inspection\, testing\, and maintenance.  This webinar will discuss key differences in orientation\, spray patterns\, response\, temperature rating\, and application. Specific topics will include residential sprinklers\, ESFR sprinklers\, CMSA sprinklers\, standard spray sprinklers\, special sprinklers\, and nozzles. \nLearning Objectives: \n1.    Identify the different spray patterns of the different sprinkler types\n2.    Differentiate between standard response\, fast response\, special response\, and quick-response\n3.    Identify the components of a sprinkler\n4.    Identify the temperature rating based on color code and proximity to heat sources \n Learn More and Register\nDetails:  \nRegistration Fees (per person): \nAFSA  Member Without CEU: FREE\nAFSA Member With CEU: $25.00\nAHJ Without CEU: FREE\nAHJ With CEU: $15\nNon-Member: $250 \nContinuing Education Credit: \nThis webinar offers: 0.1 CEUs\, 1.0 CPDs \nTo receive continuing education credits for the webinar\, you must do all of the following: \n\nRegister individually using your name that matches your fitter certification\, if applicable.\nConnect with your unique webinar link.\nDo not share or use someone else’s unique webinar link.\nAttend the webinar in its entirety\nRespond to each checkpoint question\nSubmit a completed evaluation form within 14 days of the webinar\n\nPlease check your time zone to ensure you connect at the right time: \n9:00 AM – 10:00 AM Pacific Time \n10:00 AM – 11:00 AM Mountain Time \n11:00 AM – 12:00 PM Central Time \n12:00 PM – 1:00 PM Eastern Time 
URL:https://firesprinkler.org/calendarevent/sprinkler-types-characteristics-cal-fire/
LOCATION:Online Webinar
CATEGORIES:Fitter Zone,Webinar
ATTACH;FMTTYPE=image/jpeg:https://firesprinkler.org/wp-content/uploads/2021/06/sprinklers_whitebg.jpg
END:VEVENT
END:VCALENDAR